<LOGO>
FM Transmitter Measurement Report
Created: 2025-12-17 20-41-35
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
107.50 MHz 5/5, 72 dBuV SRF2
Pilot RDS Phase Difference
0.0 kHz 0.0 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
0 kHz 1 kHz 19160 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-18,0 dBr -18,00 dBr -18,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SRF2 " 43B2 9 (Varied) 1 0 1 1 20:41, 17.12.2025
RT
"SRF2 "
AF EON
88.5, 91.7, 93.0, 93.2, 93.7, 94.0, 94.9, 95.4, 96.6, 97.3, 97.7, 99.0, 99.1, 99.4, 99.5, 99.6, 100.7, 102.5, 103.2, 104.1, 104.9 MHz 43B3, 43B1
FM Scope Max at: 1 kHz MIN: 0 kHz % above 76 kHz: 0,0000 Acquired: 2025/12/17 20.40.30 Total samples: 19160 Equivalent time: 0:15:58 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 5000 10000 15000
FM Scope MAX: -18,0 dBr MIN: -18,0 dBr AVE: -18,00 dBr % above 12,2 dBr: 0,0 Last value: -18,0 dBr (2025/12/17 20.40.30) 20.26 20.28 20.30 20.32 20.34 20.36 20.38 20.40 -15 -10 -5 0 Pm [dBr]